Nyhet -

Soft Tissue Healing Around One Piece Implants

Olimpiu L.Karancsi, Radu Sita, Emanuel A. Bratu

Abstract

One piece implants were introduced many years ago, however in the last years they were accepted as a treatment option for specific clinical cases. Aim - The aim of the study was to evaluate the probing depth values around one piece screw implants with a rough surface neck two years after loading

Methods

Forty one-piece dental implants were placed in twenty-three patients in various clinical situations. The implants were followed for two years after loading. Bone and soft tissue values were evaluated using panoramic x-rays and standard clinical measurements.

Results

All Implants showed good clinical stability two years after loading. Soft tissue adherence was very good on the implant’s neck. In cases with rigurous oral hygene no bleeding on probing was observed. The mean bone loss was 1.8 mm at the end of the study.

Conclusion and discussion

Soft tissue healing around one-piece implants with a rough surface neck was eventless, with no irritation or bleeding after two years. The results suggest that an implant neck with rough surface is appropriate for soft tissue healing.

Materials And Method

One-piece implants (MIS Uno, MIS Implants, Bar-Lev, Israel) with diameter of 3.0 mm (length 10 and 13mm) were clinically evaluated in this study. The 40 implants were placed in 24 patients in different clinical situations. The patients were all with narrow alveolar ridges but with sufficient bone height. No bone augmentation procedures were performed. The patients were all healthy, with good oral hygiene, however smoking was not an exclusion criteria.

Surgical Procedure

The implants were placed following the manufacturer protocol, with the use of a 2mm pilot drill and a 2.4mm final drill. In the maxilla, the final drill was only used in the cortical bone. A crestal incision was performed and full mucoperiosteal flaps were elevated at the site. Bone was cleaned of periosteal tissue and implant position was marked by a round bur. Then 2mm pilot drill marked the depth and angulation of the implant. For the first 2 mm depth, 2.4mm final drill was used in the cortical crestal bone. Implants were inserted using a ratchet, until final position was reached. This position was considered right below the abutment, the threads being completely covered by bone. Medication included antibiotics (Augmentin 1gr Smithkline Beecham) for 6 days and analgesics (Ketonal forte 200mg) for 3 days. Probing depths around the implants were performed after sutures placement. Measurements were taken at the distal point of the alveolar crest around each implant with a periodontal probe. Bone level and soft tissue level were considered baseline at insertion. Patients returned after 3 days and depending on periotest values a decision was

Follow Up And Examination

Soft tissue sounding was performed at insertion, at three months after placement, at one year after placement and at two years after placement. Sounding was performed using a parodontometer by Aesculap 0,2 N (20g). Measurements were made on the distal surface of the implant.

Results

One of the 40 implants failed during the osseointegration phase, probably due to the fact that the bone was extrmemly narrow at the site. All other 39 implants showed good stability during the 2 years study period. The mean value of bone loss on x-rays was 1,8mm. At the first year, probing depths tended to decrease (as shown on table 1) however, at the 2 year follow-up probing depths were generally higher than after the values found at the end of the first year. This is probably due to bone remodeling around the implant’s neck in narrow ridges. In patients with good oral hygene no bleeding on probing was observed when usihg the parodontometer Aesculap. There was no significant difference between male and female patients.

Discussion

The present clinical study evaluated the stabilization of soft tissue around a rough SLA treated surface. At the initial examination after implant insertion, probing depths showed greater values comparing to the values obtained after 3 months. This is normal, because of the healing process of the peri-implant tissues. What is of clinical value is the fact that there was no irritation of the soft tissues around the implants during the healing period which suggests that regardless of receiving a provisional or not, the gingiva recovers well and adheres on a rough surface, if certain criterias are accomplished. One piece implants with a SLA surface showed very good tissue integration, especially for the soft tissue at the implant neck. This type of implant has even today a large range of uses in almost every clinical situation, presenting a minimal bone loss and allowing insertion in narrow ridges. Large augmentation procedures can be avoided. Even after 2 years of loading no significant modifications of tissue around the implants were visible. Also the prosthetic procedures are simple in case of good positioning of the implants. A problem that can occur in time is that in the case of implant loss and abutment preparation, implant unscrewing can be difficult. This is why sufficient prosthetic space has to be created before implant insertion. Also, the clinician must be aware that only minor changes in implant insertion axis can be obtained with abutment preparation. For that reason, careful preoperative evaluation should be performed and occlusion check should be made after pilot drilling. The bone of patients differs significantly in quantity and quality and soft tissue is following these structures. Very often, patients refuse augmentative procedures, which are costly and sometimes involve significant risk factors. Therefore, the use of one piece implants with reduced diameter is still a treatment option even today, in the era of subgingival healing. One major problem of modern implant dentistry is maintaining soft tissue around dental implants. This problem is especially of great interest in the aesthetic zone. Several methods of soft tissue management evolved in the last decades, with emphasis on soft tissue transpositions and transplants. These procedures are not always in reach of the general practitioner. Implant’s design has a great influence on bone and soft tissue level, as showed in different studies. In the last 5 years, the polished neck of dental implants is loosing ground in favor of treated surfaces. Until now, most studies concentrated on bone level around implants, but this is also linked with soft tissue adherence.The fact that a 3mm implant neck allows softer tissue around it is undoubted. The question is whether a polished neck is beneficial.

Conclusions

The study demonstrated that there is no absolute need of a polished implant neck in order to prevent peri-implant tissue irritation, if a fixed gingiva around the implant can be obtained. Because of the small diameter of the implants it is possible in almost every case to obtain sufficient soft tissue thickness around the implant. Also, if the pocket depth depends on the thickness of the mucosa, the thicker the mucosa, the smaller the depth. However, if the gingiva is not fixed, problems of plaque deposits can arise and implant failure is possible. Sututring technique is also important. Two interrupted sutures should be positioned very close to the implant’s abutment to avoid gaps between implant and tissue. Initial results are promising, but further investigation and longer observation periods are needed in order to have a statement on this issue. The most indicated position for this implant type is that of mandibular lateral and central incisors, maxillary lateral incisors especially for aesthetic reasons and mandibular narrow ridges, when conditions do not allow augmentation procedures. This type of implant is not indicated in edentouluos patients due to the risk of mechanical overload. made whether to immediately restore the implant or not. All patients with negative periotest values received restorations; otherwise, waiting time was 3 months. The immediate restorations were made of acrylic resin and cemented with provisional Temp-Bond cement (Kerr). After this period, another probing depth measurement was taken and compared to data from the day of surgery.

Relaterade länkar

Ämnen

  • Utbildning

Kategorier

  • uno
  • mis
  • mis sweden
  • tandimplantat
  • implants
  • implantat
  • soft tissue healing
  • one piece
  • retrospective clinical study
  • narrow

Kontakter

Katarina Lundin

Presskontakt Office Manager +46 (0)732-30 52 63

Relaterat innehåll

The use of 6mm long implants in cases with limited bone hight

Olimpiu L.Karancsi, Radu Sita, Emanuel A. Bratu It can be concluded that short implants are a viable treatment option when splinted, at least for 6 months after loading. Short implants seem to be the optimal option as supplementary implants in free end situations, especially in the rear mandible areas, when combined with standard implants.

Publicerade artiklar 2010

En kort presentation av de artiklar, som publicerats världen över, under 2010